      GGD AC low voltage distribution cabinet

      GGD AC low voltage power distributing cabinet is applicable to power distribution system of AC50Hz, and with a rated operational voltage of 380V, rated operation current to 3150A in power users like generators, transformer substation, and mining enterprises, and it is used in power transformation, distribution and control of driving motor, illumination and power distribution equipment.

      products detial


      What we can do ? different country different requirement all we can offer.

      Mid-voltage ( kV)

      3.6~35kv

      (E.g. 35,33,24,22,20,18,15.75,13.8,13.2,12,11,10.5,10,7.2,6.6,6.3,6 etc.)

      To Low voltage ( V)

      100-660V

       (E.g. 100,110,115,120,127,208,200,220,230,240,346,380,400,410,415,440,480,660 etc.)

      Frequency (HZ)

      50Hz or 60Hz

       Ⅰ.Application

      GGD AC low voltage power distributing cabinet is applicable to power distribution system of AC50Hz, and with a rated operational voltage of 380V, rated operation current to 3150A in power users like generators, transformer substation, and mining enterprises, and it is used in power transformation, distribution and control of driving motor, illumination and power distribution equipment. 

      Ⅱ.Environmental conditions 

      1.Ambient air temperature: -15℃~+40℃
      Daily average temperature: ≤35℃
      When the actual temperature exceed the range, it should be used by reducing the capacity accordingly.
      2.Transport and store temperature: -25℃~+55℃. do not exceed +70℃ in short time.
      3.Altitude: ≤2000m
      4.Relative humidity: ≤50%, when temperature is +40℃ When temperature is low , larger relative humidity is allowed. when it is +20℃, relative humidity can be 90%. Since the temperature change will make out condensation.
      5.Installation inclination: ≤5%
      6.Applicable in the places without corrosive and flammable gas.
      Note: Customized products are available

      Ⅲ.Specification 

      Type

      Rated voltage(V)

      Rated current(A)

      Rated short circuit dropout current(kA)

      Rated short time withstands current(Is)(kA)

      Rated peak value withstand current(kA)

      GGD1

      380

      A: 1000

      15

      15

      30

      B: 600(630)

      C: 400

      GGD2

      380

      A: 1500(1600)

      30

      30

      63

      B: 1000

      C:600

      GGD3

      380

      A: 3150

      50

      50

      105

      B: 2500

      C: 2000

      Dimension (mm)

      Height

      2200

      width

      600, 800, 1000

      depth

      600, 800

       

      specification

      unit

      data

      Rated voltage

      kv

      11,33,35,40.5

       

      Rated current

      rated current of bus line

      A

      630,1250,1600,4000

      rated current of circuit breaker

      A

      630,1250,1600,4000

       

      Insulation level

      1min power frequency withstand voltage

      KV

      95/110

      lightning impulse withstand voltage

      KV

      185/215

      power frequency withstand voltage of auxiliary circuit and control circuit

      V

      2000

      Rated frequency

      HZ

      50/60

      Rated short circuit breaking current

      KA

      20/25/31.5

      Rated short-time withstand current of short circuit duration

      KA/4s

      20/25/31.5

      Rated current of peak withstand

      KA

      50/63/80

      Rated making current of short circuit 

      KA

      50/63/80

      Rated voltage of control loop

      V

      DC:110 220  AC:110 220

       

      Protection leve

      switch equipment shell



      compartment(cupboard door open)



      Ⅳ.Features

      1)GGD low voltage switchgear can be divided in to receiving cabinet, bus connecting cabinet, feeding cabinet, motor control cabinet, reactive power compensation cabinet and lighting distribution cabinet

      2)The cabinet body of GGD is in the form of general cabinet. The cabinet frame is welded and assembled with 8MF cold-formed steel. The frame parts and the special supporting parts are supplied by the fixed-point steel manufacturer to ensure the accuracy and quality of the cabinet.

      3)There are different numbers of heat sinkholes at the upper and lower ends of the cabinet, so that the sealed cabinet forms a natural ventilation channel from bottom to top to achieve the purpose of heat dissipation.

      4)Cabinet door is connected with the frame with a rotating shaft type movable hinge, which is convenient for installation and disassembly. The folding part of the door is embedded with a mountain type rubber plastic strip, which can be prevent the door from directly colliding with cabinet body, improve the protection of the product.

      5)The instrument door with electrical components is connected to the frame with multiple strands of soft copper wire. The installation parts in the cabinet and the frame are connected with knurled screws, and the whole cabinet constitutes a complete grounding protection circuit.

      6)The top cover of the cabinet can be removed when necessary to facilitate the assembly and adjustment of the main bus on site. The cabinet is equipped with lifting rings on the four corners, used for lifting and shipping.

      0040+


      ×
      Add WeChat friends

      Click to copy the WeChat ID

      WeChat ID:+86 180-7778-0057

      Copy successfully
      WeChat ID:+86 180-7778-0057
      Add WeChat friends
      Go to WeChat to add friends

      WhatsApp

      Tel

      0771-3860772
      7*24 Service Hotline

      ?

      WeChat

      二維碼Scan to add WeChat
      TOP
      亚洲 自拍 另类 欧美 综合_蜜桃成人无码区免费视频网站_丝袜偷拍欧美主播另类_亚洲国产精品第一区二区三区

        <form id="fvlnd"></form>
        <form id="fvlnd"><th id="fvlnd"><th id="fvlnd"></th></th></form>

          <sub id="fvlnd"><listing id="fvlnd"><menuitem id="fvlnd"></menuitem></listing></sub>
          <listing id="fvlnd"><listing id="fvlnd"><meter id="fvlnd"></meter></listing></listing>