      Products
      PRODUCTS
      Products

      YB-12/0.4-口 High-voltage/Low-voltage Prefabricated Substation (European)

      YB-12/0.4-口 HV/LV Prefabricated Substation is a kind of compact power distribution device that integrates high-voltage electrical devices with transformer and low voltage electrical devices. It is widely applied to buildings in urban and rural areas, residential communities, high-new-tech development zones, small and medium sized factories, mining areas, oil fields, temporary construction sites and so on, is used for electric energy receiving and distribution in power distribution system.

      products detial


      What we can do ? different country different requirement all we can offer.

      Mid-voltage ( kV)

      3.6~35kv

      (E.g. 35,33,24,22,20,18,15.75,13.8,13.2,12,11,10.5,10,7.2,6.6,6.3,6 etc.)

      To Low voltage ( V)

      100-660V

       (E.g. 100,110,115,120,127,208,200,220,230,240,346,380,400,410,415,440,480,660 etc.)

      Frequency (HZ)

      50Hz or 60Hz

      Ⅰ.Overview

      YB-12/0.4-口 High-voltage/Low-voltage Prefabricated Substation (hereinafter referred to as cubicle substation or European cubicle substation) is a kind of compact power distribution device that integrates high-voltage electrical devices with transformer and low voltage electrical devices. It is widely applied to buildings in urban and rural areas, residential communities, high-new-tech development zones, small and medium sized factories, mining areas, oil fields, temporary construction sites and so on, is used for electric energy receiving and distribution in power distribution system.

      II. Model and description

      image

      Ⅲ.Environmental conditions

      1.Ambient temperature: outdoor equipment: -15℃ ~ + 55℃, indoor equipment: -15℃ ~ + 45℃;mean value within 24h should not exceed +35°C;
      2.Solar radiation: ≤ 1,000 W/m;
      3.Arelative humidity:The average daily relative humidity is not more than 90%(+25 ℃), the average monthly relative humidity is not more than 90%, temperature condensation, may condensation;

      4.Altitude: ≤1000m .

      5.Earthquake intensity: not exceeding 8 degrees

      6.Vibration: horizontal acceleration 0.5g, vertical acceleration 0.2g;

      7.Thunderstorm day: heavy minefield (Td> 60);

      8.Reice thickness: ≤ 10 mm;

      9.Wind speed: The average wind speed is 3.0m/s, and the maximum wind speed does not exceed 35m/ seconds.

      10.Daily average relative water vapor pressure is ≤ 2.2kpa, Monthly average relative water vapor pressure is ≤ 1.8kpa;

      11.Seismic horizontal acceleration: no more than 0.4m/s, vertical acceleration: not greater than 0.2m/s.

      12.The installation site should be no conductive, dusty, hazardous, corrosive, inflammable and explosive materials harmful to 13.metals and insulators.

      14.The special working conditions shall be negotiated by the manufacturer and the user and corrected according to the standard.

      Ⅳ.Specification



      Main technical parameters

       

       

       

       

       

       

       

       

       

      HV unit

      Rated frequency

      Hz

      50

      Rated voltage

      kV

      7.2 12 24 40.5

      Rated current of main bus

      A

      630 1250 1600

      Rated short-time withstand current / duration

      kA/s

      20/4 25/3 31.5/4

      Rated peak withstand current

      kA

      50 63 80

      1min power frequency withstand voltage (to-ground/between open contacts)

      kV

      32/36 42/48 65/79 95/115

      Lightning impulse withstand voltage (to-ground/between open contacts)

      kV

      60/70 75/85 125/145 185/215

      Rated short-circuit breaking current

      kA

      20 25 31.5

      Ground loop short-time withstand current / duration

      kA/s

      20/2 20/4

      Rated short-circuit making current of main loop

      kA

      50 63 80

      Rated active load breaking current

      A

      630

      Rated closed loop breaking current

      A

      630

      Rated transfer current

      A

      1700

      Mechanical life peroid

      times

      3000 5000 10000

       

       

       

       

      LV unit

      Rated frequency

      Hz

      50

      Rated voltage

      kV

      0.4/0.23

      Rated insulation voltage

      V

      690

      Rated current of main loop

      A

      100~3200

      Rated short-time withstand current

      kA/s

      30/1 50/1 100/1

      Rated peak withstand current

      kA

      63 105 176

      5s power frequency withstand voltage

      kV

      2.5 3.75

       

       

       

       

       

       

      Transformer unit

      Rated frequency

      Hz

      50

      Rated voltage

      kV

      7.2 12 24 40.5/0.4

      Rated capacity

      kVA

      30~1600

      1min power frequency withstand voltage

      kV

      25/20 35/28 55/50 85/75

      Lightning impulse withstand voltage

      kV

      60 75 125 170

      Impedance voltage

      4~6

      Tapping range

      ...

      ±×2.5% ±×5%

      Connection group

      ...

      Y,yn0 D,yn11

      Type

      ...

      Oil-immersed type, dry type

       

      Cabinet body

      IP code of HV and LV chambers

      ...

      IP33D

      IP code of transformer chamber

      ...

      IP23D

      Sound level (oil-immersed type/dry type)

      dB

      ≤50/55



      Ⅳ.Features

      Prefabricated transformer substation Main features

      System voltage:12kV(24kV,36kV is available) rated high voltage current:630A or more;

      Collocating 3D transformer, reduce loss, upgrade the capability to 11 grade;

      Collocating 3D transformer, upgrade insulation heat-resistant to H grade, can work long time in 180 setting;

      Collocating 3D transformer, lessen 1/4-1/5 of the box cubage;

      Design and make the ring network or users end as to the users requirements;
      Design the box to steel plate configuration, complicated configuration or garden landscape configuration as to the users requirement;

      Fix auto-parts, realize Three remote, check the data in distant, thief proof and power fare management;

      Completely whole set, intelligent, little area, low investment, short project, ingoing load center, energy-saved and the lower loss, convenient assembly, adapted to setting.

      Ⅴ.Structure

      Prefabricated transformer substation Structure character

      1.Small volume, convenient installation and maintenance, low noise, low loss, full protection.

      2.Have three enclosure forms: standard type, reinforces type, and integrated type according to low voltage and

      feeding requirements.

      3.This product is the latest and absorbing foreign advanced technology, combined with domestic actual situation of

      research and development, and called Localization of American cabinet.

      4.Ring network power supply, double power supply or terminal power supply systems, the substation, power

      distribution, metering, compensation, control and protection devices.

       

      Features:

      1) Smaller occupied area
      2) Firm and reliable
      3) Easy to move, beautiful and practical
      4) Its cost is low, and the installation period is short

      copy (2) - 800


      ×
      Add WeChat friends

      Click to copy the WeChat ID

      WeChat ID:+86 180-7778-0057

      Copy successfully
      WeChat ID:+86 180-7778-0057
      Add WeChat friends
      Go to WeChat to add friends

      WhatsApp

      Tel

      0771-3860772
      7*24 Service Hotline

      ?

      WeChat

      二維碼Scan to add WeChat
      TOP
      亚洲 自拍 另类 欧美 综合_蜜桃成人无码区免费视频网站_丝袜偷拍欧美主播另类_亚洲国产精品第一区二区三区

        <form id="fvlnd"></form>
        <form id="fvlnd"><th id="fvlnd"><th id="fvlnd"></th></th></form>

          <sub id="fvlnd"><listing id="fvlnd"><menuitem id="fvlnd"></menuitem></listing></sub>
          <listing id="fvlnd"><listing id="fvlnd"><meter id="fvlnd"></meter></listing></listing>